您选择的条件: GE Liang-Quan
  • Simulation of radiation dose distribution and thermal analysis for the bulk shielding of an optimized molten salt reactor

    分类: 核科学技术 >> 裂变堆工程技术 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》

    摘要: The Chinese Academy of Science has launched a thorium-based molten-salt reactor (TMSR) research project with a mission to research and develop a fission energy system of the fourth generation. The TMSR project intends to construct a liquid fuel molten-salt reactor (TMSR-LF), which uses fluoride salt as both the fuel and coolant, and a solid fuel molten-salt reactor (TMSR-SF), which uses fluoride salt as coolant and TRISO fuel. An optimized 2 MWth TMSR-LF has been designed to solve major technological challenges in the Th-U fuel cycle. Preliminary conceptual shielding design has also been performed to develop bulk shielding. In this study, the radiation dose and temperature distribution of the shielding bulk due to the core were simulated and analyzed by performing Monte Carlo simulations and computational fluid dynamics (CFD) analysis. The MCNP calculated dose rate and neutron and gamma spectra indicate that the total dose rate due to the core at the external surface of the concrete wall was 1.91 Sv/h in the radial direction, 1.16 Sv/h above and 1.33 Sv/h below the bulk shielding. All the radiation dose rates due to the core were below the design criteria. Thermal analysis results show that the temperature at the outermost surface of the bulk shielding was 333.86 K, which was below the required limit value. The results indicate that the designed bulk shielding satisfies the radiation shielding requirements for the 2 MWth TMSR-LF.

  • A new digital Gaussian pulse shaping algorithm based on bilinear transformation

    分类: 核科学技术 >> 核探测技术与核电子学 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》

    摘要: Nuclear pulse signal needs to be transformed to a suitable pulse shape to remove noise and improve energy resolution of a nuclear spectrometry system. In this paper, a new digital Gaussian shaping method is proposed. According to Sallen-Key analog Gaussian shaping filter circuits, the system function of Sallen-Key analog Gaussian shaping filter is deduced on the basis of Kirchhoff laws. The system function of the digital Gaussian shaping filter based on bilinear transformation is deduced too. The expression of unit impulse response of the digital Gaussian shaping filter is obtained by inverse z-transform. The response of digital Gaussian shaping filter is deduced from convolution sum of the unit impulse response and the digital nuclear pulse signal. The simulation and experimental results show that the digital nuclear pulse has been transformed to a pulse with a pseudo-Gaussian, which confirms the feasibility of the new digital Gaussian pulse shaping algorithm based on bilinear transformation.

  • A nuclear spectrum generator for semiconductor X-ray detectors

    分类: 核科学技术 >> 核探测技术与核电子学 提交时间: 2023-06-18 合作期刊: 《Nuclear Science and Techniques》

    摘要: A nuclear spectrum generator for semiconductor X-ray detectors is designed in this paper. It outputs step ramp signals with random distribution in amplitude and time according to specified reference spectrum. The signals are similar to the signals from an actual semiconductor X-ray detector, and can be use to check spectrum response characteristics of an X-ray fluorometer. This helps improving energy resolution of the X-ray fluorometer. The spectrum generator outputs step ramp signals satisfying the probability density distribution function of any given reference spectrum in amplitude through sampling on the basis of 32-bit randomizer. The system splits 1024 interval segmentation of the time that the step ramp signals appear, and calculates the appearance probability of step ramp signals in different intervals and the average time between the time intervals, by random sampling. The step ramp signals can meet the rule of exponential distribution in time. Test results of the spectrum generator show that the system noise is less than 2.43 mV, the output step ramp signals meet the Poisson distribution in counting rate and the probability density distribution function of the reference spectrum in amplitude. The counting rate of the output step ramp signals can be adjusted. It meets the rule of the output signals from semiconductor X-ray detectors, such as Si-pin detector and silicon drift detector.